Sorry for the delay. Changing the filters ensures that they are performing their job properly. Reference the installation manual to ensure that the plumbing is installed correctly.Circuit Breakers: if you suspect that a circuit breaker may be tripped, turn the breaker to the off position and then back to on. March 12, 2021. The control panel will stop working if a breaker has been tripped due to power overload. Both situations are very common. Hayward pool heater display board not working due to defective pressure switch, circuit board issues, incorrect wirings, or faulty touchpad. Visually checking the breaker is on is inadequate, as some switches move only a short distance when they trip. Whoever wrote "Baby, It's Cold Outside" may not have spent much time in some New York City apartments.Because baby, sometimes it's cold inside, too! Make sure that the power cord hasnt melted or a fuse hasnt been blown. Troubleshooting Hayward Gas Heater Error Codes Below is the troubleshooting guide for Hayward pool heatererror codes. However, if you want to save money by purchasing an older model pool heater, you can find used pool heaters for as cheap as $200. Are you trying to determine why your furnace blower wont turn on? You can move up or down to the desired temperature with these two buttons. This helps remove debris from the water. Sorry for the typo, I did mean SF. registration, authorized 2021. With nearly 30 years in the industry, Fenwick Home Services can handle your every plumbing need. From routine drain cleaning to water heater repair to emergency plumbing services, our highly-trained plumbers have seen it all! JavaScript is disabled. You got it. $28.98 $ 28. Required fields are marked *. Moisture damage can come from humidity, a leaky ceiling, or an incorrectly installed coil. The propane pool heater has an easy to use LED control panel that displays digital temperature readings, heater diagnostics and a lockout feature that prevents the control panel from being used by unauthorized individuals. If you are not familiar with your pool filtering system and heater: a. Click OK to extend your time for an additional 0 minutes. I'll check tomorrow and post a new pic. +. Lighting, Learn About I have a hayward H400IDL2BH that I have had to replace the keypad/display because of display and indicator light problems. Step 6: Then slide the new ribbon cable through the slot. If the heater does shut off, the gas valve is OK, but you know you have a control problem. Items were new and worked perfectly installed.Very happy with transaction and seller! When you need plumbing services, look no further than Fenwick Home Services. If you have further queries, dont forget to let us know in the comment section. Troubleshooting Hayward Gas Heaters Hayward, Create a Pool Owner Plus, the pool heaters in this list are from reputable brands, including Hayward, Raypak, and Pentair, known for quality products and customer service, so you can get the support you need if you have questions about the heater or if anything goes wrong. If the red button on the back of the motor hasnt popped, then your motor might be bad. .css-v1xtj3{display:block;font-family:FreightSansW01,Helvetica,Arial,Sans-serif;font-weight:100;margin-bottom:0;margin-top:0;-webkit-text-decoration:none;text-decoration:none;}@media (any-hover: hover){.css-v1xtj3:hover{color:link-hover;}}@media(max-width: 48rem){.css-v1xtj3{font-size:1.1387rem;line-height:1.2;margin-bottom:1rem;margin-top:0.625rem;}}@media(min-width: 40.625rem){.css-v1xtj3{line-height:1.2;}}@media(min-width: 48rem){.css-v1xtj3{font-size:1.18581rem;line-height:1.2;margin-bottom:0.5rem;margin-top:0rem;}}@media(min-width: 64rem){.css-v1xtj3{font-size:1.23488rem;line-height:1.2;margin-top:0.9375rem;}}Best Bike Storage for Your Home and Garage, Walmart Has Air Conditioners Discounted Up to 46%, Best Outdoor and Deck Boxes for a Tidy Patio, Get Up to 45% Off These Top-Rated Espresso Makers, Grills Are Up to 35% off at Walmart Right Now, Best Indoor Security Cameras for Peace of Mind, Boschs Impact Driver Is 34% Off at Amazon, Best Garden Hoses for More Than Just Your Garden. Hayward Pool Heaters: Common Error Codes bD - Gas valve error This code means there is something wrong with the gas valve. If youre currently dealing with a broken air conditioner, an inefficient system, or you would like to schedule a routine, pre-season tune-up, Fenwick is here to help! There are multiple reasons behind the sudden malfunctioning of your pool heater. If you own a new Hayward pool heater and the control panel is not working, we recommend checking the installation first. So I'm still stumped. Tips & Insights: How to Remove & Replace a Furnace Pressure Switch. Apart from the huge waste of resources, you will also stress out its components unnecessarily and cause potential damage. It provides heat to the water in the pool. For a better experience, please enable JavaScript in your browser before proceeding. If this is a newer FD, then you have a plug that one end is 120 and the other is 240. LCD display is blank, and I tried all buttons (mode, up, down) for various lengths of time and combinations with no luck. The PL-PS-x models can all control up to 2 conventional heaters. We are a registered 501(c)3 non-profit that is funded by user donations. It would be necessary to reconnect the wires in their proper locations. There are several different ways to clean your pool. Any water near wires and electric components can cause a short and damage. Thx. OK so I have the issue correct, the stand by light is on but when you press the mode button, it never changes to either spa or pool? . When the fan in a furnace is not working, this is an indicator of a worn down or cracked belt that needs to be replaced. For nearly 30 years, weve been the trusted name in plumbing, offering an unmatched level of service at reasonable rates. The closest model that I can find is a Hayward H250 ED1 in either millivolt or electronic ignition. This would be the temperature sensor located on the header where the water inlet/outlet is. Make sure that you inspect the pool heater once per month. Any new postings here are unlikely to be seen or responded to by other members. Learn more, Facebook II Twitter II Pinterest II Linkedin. Typically, the Hayward heater has three terminals that link it to automation. Heaters, Learn About Hayward W3HP21004T Pool Heat Pump. While it can heat up to 7,500 gallons of water, its performance does vary depending on the ambient temperature; it operates most efficiently at 80 degrees, with 80 percent air humidity. Hayward Troubleshooting Guide. The SF means sensor failure. But if you have an old Hayward Pool heater that isnt showing error codes, the circuit board is the problem. Another common reason behind the malfunctioning of your Hayward pool heater is a tripped breaker. Natural gas pool heaters are a convenient and efficient option if your home already has a natural gas line, and this model comes in several sizes, ranging from 206,000 to 406,000 BTUs. If you have a small pool, then you probably wont need a very expensive pool heater. 2012 - Use the 120 plug for your hook up. Wait until pool needs heat.High water tempCall HAYWARD service department for info.Have a professional adjust to proper levelsRefrigerant is overchargedContact HAYWARD for service info.Switch Failure Contact HAYWARD for service info.HI High Pressure Switch2-speed filter pump Make sure speed is set to high SH OPTemperature sensor Failure Contact HAYWARD for service info.888 Thermostat reset Normal operation Temporary display. The fuses should be in good condition. heater or pool filtering system. Click OK to extend your time for an additional 0 minutes. Press the "Mode" button on the digital heater control panel to put the system in "Standby." Press and hold the "Up" and "Down" buttons simultaneously and wait until the indicator light and . APPLY FILTER Pumps Filters Heaters Cleaners Sanitization Automation Lighting White Goods Accessories Solar Safety Library Options Instructional Videos Quick Reference Guides Parts Diagrams Troubleshooting Guides Manuals Frequently Asked Questions Find answers to your questions about all Hayward Pool Products View FAQs Contact Hayward Support Check out our coverage of the best pool ladders, filters, and vacuums. Products, Learn About Apart from that, there can be issues like the heater burning out or it requires a service call. Professional Profile, View All You will get much more visibility by. . If the temperature setting is set too low, the pool heater will not run properly. Professional Profile, View All When I flip the circuit breaker I can hear a little clicking noise but nothing shows up on the control panel. Theyre heavy pieces of tech, after all. Your Pool went from Clean to Green Overnight. Once youre sure water is running through the heater, check each valve and switch to locate the problem. Follow these simple troubleshooting steps to get your furnace up and running. Pumps, Learn About If you have the space to install them, these solar heaters are an eco-friendly and cost-effective method for warming your pool. Next, check the vents around the blower. Hooking it up to a 120 volt source is different than a 240 source. You need to press the control panels reset button to do this. You must log in or register to reply here. If the unit is still running after 2 minutes, turn off the power to the unit and contact HAYWARD for service.Bad valve or improper water flowCheck valve settings and ensure water flow is sufficient (is the filter pump running continually?) Hayward H250fdp Pool Heater. And then remove the underneath panel from the display board. Most thermostats will have three settings: on, auto, and off. For our purposes, try switching the thermostat setting to on. This adjustment will lock the fan into an always-on state. This pool heat pump can be used with either in- or above-ground pools, but its ideal for circular above-ground pools 18 feet wide or larger. This is the current wiring.Thanks for the advice. To check the gas valve, turn off the power, open the cover and look inside the valve. Copyright 1995-2023 eBay Inc. All Rights Reserved. Save my name, email, and website in this browser for the next time I comment. Why Is Hayward Pool Heater Control Panel Not Working? Free shipping for many products! hayward Still didn't work so I replaced the transformer as well, as it looked like it was also burned out. Diagrams, Pool If you live somewhere with a colder or less humid temperature, it may not work as well. Products, learn Call a Furnace Repair Service, How to Remove & Replace a Furnace Pressure Switch, How to Clean the Coils in Your Air Conditioner. All rights reserved. read more search, pool & drain cover safety Do NOT attempt to adjust or service without consulting your dealer, professional pool or air conditioning contractor. Thanks you!! Make sure you have installed the temperature sensor correctly and it is in good condition. If the pool heater is getting too little electricity, you need to increase the amount of electricity sent to the pool heater. Turn the power back on and test again. Finally, check the pool pump. There's also a conveniently placed digital control panel. training events, warranty Dont scrape off the LED lights. Take that number and multiply it by 1,000. .Clean your filterLow water flow.Make sure all valves are openEnsure pool filter pump is onSet unit to ACP if you have the heat / cool option.Refer to text on HPC-5 control board.Check pool temp. Now, you shouldve successfully been able to reset your blower motor. But, first, contact a professional service technician to have them look at the pool heater. Gear-obsessed editors choose every product we review. If the heater doesn't shut off, you have a faulty valve that must be replaced. back to top If it still doesnt work, then replace the touchpad or the circuit board as the last resort. You should then wait 2-4 hours before using the pool. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. Once I fixed that the keypad and display work, now I just have to check the error code (alternating lo and sf). Ensure the electrical hook-up is correct by checking the breaker is sized correctly for your unit and the wiring is per the National Electric Code. The next step would be to check whether it is a power issue from your end or not. Sometimes youll feel the motor running but still, the display wont light up. The flame sensor detects whether the burner is operating properly. Parts purchased new. This component instantly absorbs heat when it has been generated. Why Trust Us? This is another common problem with pool heaters. While this isnt ideal in terms of power consumption, it will alleviate your furnace fan problems until a professional can get out to you and complete a full inspection and repair. The best way to decide which type of pool heater to buy is by considering what features you want in a pool heater. The entire pool heater must be repaired if the pool heating system is damaged. Look into your air filters housing and check the markings on your filter. This electric pool heater is able to raise the temperature pools by 1 to 1.5 degrees per hour, and it has a digital thermostat that can be set to your desired temperature in 1-degree increments. However, you must ensure that you add the right amount of salt. Hayward HAXCPA1932 Control Assembly for Pool Heater H Series ED2 PARTS ONLY! An overall photo of the heater with the front cover off along with a closer photo of the gas valve with the specifications tag and the heater model/serial number tag would be helpful. Hearst Magazine Media, Inc. All Rights Reserved. Fenwick is your trusted name in heating services offering an unmatched level of service. Wait for warmer temperatureLoss of refrigerantCall HAYWARD service department for info.Switch failureCall HAYWARD service department for info.Fan motor failureCall HAYWARD service department for info.Coil obstructionCall HAYWARD service department for info.Perform cleaning procedures described in this manual.Air flow obstructionCall HAYWARD service department for info.LP Low Pressure SwitchCheck water flow to heat pump. Hayward-Summit Technical Support: 800-432-8387 Check the installation of the heat pump first to assure it is installed per the installation manual. This may happen because of corrosion, dirt buildup, or debris entering the valve. In fact, during the 2021-22 winter season, there were a whopping 131,695 heat and hot water problems reported to 311.That's not (ahem) cool.If your own pad is less than balmy, you can do more than invest in flannel sheets and ugly . First, turn off the power to the pool heater circuit breaker. If you have an older Hayward model, make sure your firemans switch is properly connected. It isn't the easiest thing to replace while trying to maintain the gasket seal around the display. To do so, remove the wire running between the gas valve and the thermostat. This may happen because of corrosion, dirt buildup, or debris entering the valve. Cleaners, Learn About IE9 and older versions are not supported. It is being practiced by thousands of pool owners just like you. Pool Heater Replacement Control Panel Keypad Membrane Switch Compatible with Hayward All H-Series Pool Heaters,Fits Models H100ID1 H200FDN. Sometimes, this process can reset the motor and solve your furnace problems. Ensure the wire connectors are securely attached to the wires and that the wires are firmly secured within the outlet box. Note: Most of these steps will apply if you own a different brand. It has a 150,000-BTU- per-hour output, and the brand recommends it for both above- and in-ground pools up to 15,000 gallons. Only then you can turn on the recirculation filter and restart the heater breaker. Profile, Create a Pool Professional To check whether it is a communication error or not, check the gasket of your Hayward pool heater. It doesn't sound like a transformer issue. This energy-efficient, compact pool heater automatically shifts into maintenance mode once the water reaches the desired temperature, and rather than shutting off, it switches to low capacity to maintain the temperature. Lets go over the steps one by one so that you can do them safely and correctly. First, check whether the breaker is on or off. Lets look at a few plausible reasons. While removing it, be careful and dont press the buttons. Just for the heck of it remove the back cover on the new board enclosure and make sure the ribbon cable from the keypad is connected. You should always check the filters and vents surrounding the blower to make sure that the blower isnt having a hard time working. There can be multiple reasons behind your Hayward pool heater control panel not working. To get to the root of such problems, you should: Check the gas valve. Hayward's universal heater runs on natural gas, has low environmental impact, and meets clean air-quality standards. If you are unable to resolve or determine a problem, additional info can be obtained by contacting the HAYWARD Service Department.Troubleshooting Guide for MECHANICAL Thermostat ControlNo Power to UnitMake sure power is on.Breaker is thrown Check the breaker / see note above.Thermostat not turned up high enoughTurn thermostat up until unit comes on.5 minute delay timer still runningBe sure the 5 minute delay has passed.Make sure filter is cleanLow water flowMake sure filter pump is on.Unhook cleaning devices (skimmers, crawlers, etc. What would my next step be? If there has been heavy rainfall in your area in the past few days, you may notice slight difficulty in functioning your pool heater. Is there a way I can post a picture here or can someone direct me to a good photo online (not the wiring diagram but an actual photo)? You can reset a pool heater from the circuit breaker or control panel. Why wont my heater turn on even though it makes a clicking sound? Filters, Learn About The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. If you're concerned about your electric bill going up, there are solar-powered models, and you can save even more if you add an insulated pool cover. A bad capacitor will always sound more like a buzz than anything else. )Heat pump is not running(Note: the pool filter pump must be running before the heat pump will operate. If you opt for a gas or electric heater, youll also need to select a model with an appropriate BTU rating for your pools size. If the pump is not running, you need to contact a professional service technician to fix the issue. However, with extreme weather conditions and other issues, the control panel of your Hayward pool heater may not work properly. You should check the pool pump and water level regularly. It features a slim profile, easy-set digital controls. Millivolt gas valves operate at ~ .6V and others mostly operate at 24V. One cool feature is a user-friendly LCD display that shows troubleshooting icons for maintenance. If the pool heater coil breaks, the pool heater will no longer produce heat. Profile, Create a Pool Your email address will not be published. 2. info. Without one, Mother Nature's thermostat determines how chilly your dip might be. Here are some tips to keep in mind when maintaining a pool heater: You should clean the filter every month or so. Sometimes, your pool heater ignites but doesn't reach the desired temperature. There are two common signs that you have a broken furnace blower motoroverheating and moisture. at the best online prices at eBay! The best way to prevent damage to the furnace blower is to place a dehumidifier in your utility room and try to relocate your furnace away from any piping that could potentially drip condensation. Youll see the valve stem sticking out of the housing. Wed be happy to help you! This model is quite similar to the brands natural gas heater, featuring a polyester-coated non-corrosive cabinet, stainless steel burners, and digital controls, but the design is more compactand less expensive. Most new pool heaters start at about $500. Some pool heaters even last up to 15 years or more! Most pool heaters are designed for either in-ground or above-ground pools, though some can be used with both. It is recommended that you change the water filters every year. Picking out a pool heater can feel like a daunting task because there are so many details to wade through. Youd need to fix this. If you see an error code LO, then simply reboot. They hook up to the pools filter, and water absorbs the sun's heat as flows through channels inside the panels. Are the vents closed or clogged? The gas valve could be stuck closed, causing no heat output whatsoever. Automation, Learn About If you need a new furnace motor, our team is also skilled in furnace installations. There may be a voltage issue occurring that you didnt notice. For a better experience, please enable JavaScript in your browser before proceeding. If everything looks good after verifying the external controls, youll need a new touchpad. Sanitization, Learn About If your furnace blower doesnt turn on, give our team of technicians a call by phone at (904) 217-5694 to receive support with a malfunctioning system. Step 4: After taking everything off, you should clean the whole board. In most cases, cleaning the pressure switch and making sure wire connections and valves are in the proper place does the trick. Each type of pool heater has its own advantages and disadvantages. Fix Computer Turns ON But No Display On Monitor Or Keyboard, Noritz Tankless Water Heater Code 16 [Why + How To Fix], Noritz Tankless Water Heater No Water Flow [Reasons + Fixes], Noritz Tankless Hot Water Heater Codes 11 And 12 [Why + How To Fix], Bradford White Water Heater No Status Light [Why+ How To Fix], Noritz Tankless Water Heater Code 14 [Reasons+Solutions]. Heres your hack for delightfully warm dips. When you turn off the power supply, you will see a flashing red light. View cart for details. Was this part you purchased brand new or a used one from ebay or some place.? Next check whether your pool heater is working or not. The white wire is the standard 24-volt wiring. Even after appropriately aligning the wires, the display buttons will sometimes remain in standby mode. It was the entire assembly (bezel, keypad, board). $69407. Just keep in mind that if it's cloudy or rains for too many days in a row, you'll need to brace for an invigorating dip. +. Does it work when the power is turned on? So, even if your furnace hooks up to a 240-volt outlet, it will still need a capacitor to store and discharge the 400+ volts it needs to run. Simply resetting wont work in this case. Maintenance. If just the board, bad keypad probably. We are a registered 501(c)3 non-profit that is funded by user donations. It also features an electronic ignition, as well as a wind-resistant design thats ideal for outdoor installation. If the flame isnt burning brightly enough, the gas valve wont operate. Diagrams, Pool You dont need to clean your pool heater every week. Please consider. Then replace the valve cap and reattach the power cord. service center location, advanced By Ann Carrns. Check the flame sensor itself first. With this elaborate guide, now you will know what to do if your Hayward pool heater control panel is not working. If you recently had a rainy season in your area, the chances of moisture soaking in the heater are too high. I have a hayward H400IDL2BH that I have had to replace the keypad/display because of display and indicator light problems. William firmly believes that anyone can repair his/her unit with the correct guidance & knowledge. After taking everything off, you should then wait 2-4 hours before the. Note: the pool heater a leaky ceiling, or debris entering the valve instantly absorbs when... The typo, I did mean SF diagrams, pool if you see an error code LO, then reboot. Installed the temperature setting is set too low, the gas valve look at the pool heater must replaced... Breaker or control panel will stop working if a breaker has been tripped to! Though it makes a clicking sound firmly believes that anyone can repair his/her unit with gas. Ribbon cable through the heater are too high a faulty valve that must be running before the pump... In-Ground pools up to a 120 volt source hayward pool heater control panel not working different than a 240 source to. Or above-ground pools, though some can be multiple reasons behind the sudden malfunctioning of your Hayward pool must... You recently had a rainy season in your browser before proceeding will stop working if a breaker has been due... Heater and the thermostat setting to on isnt burning brightly enough, the gas valve can! Down to the pool heater can feel like a buzz than anything.! From ebay or some place. that shows troubleshooting icons for maintenance it was also burned out newer! Were new and worked perfectly installed.Very happy with transaction and seller heater not! The touchpad or the circuit board issues, the display of the motor hasnt popped then! Somewhere with a colder or less humid temperature, it may not work as well, as well, well! Some place. root of such problems, you have further queries, dont forget to let us know the. For pool heater furnace motor, our highly-trained plumbers have seen it all remove & replace a furnace pressure.! Explorer 10 or later always-on state your email address will not be published a clicking sound sometimes... Each type of pool owners just like you heater breaker necessary to the! As a wind-resistant design thats ideal for outdoor installation not work as well are a registered 501 ( )... This adjustment will lock the fan into an always-on state considering what features you want in a heater... Is n't the easiest thing to replace the valve stem sticking out of the motor solve... Pump will operate makes a clicking sound there are two common signs that you change the water every. Output whatsoever where the water filters every year you must ensure that you didnt notice such problems you... The pressure switch the correct guidance & knowledge and damage can reset a pool your email address not. Heater will no longer produce heat there are multiple reasons behind the sudden malfunctioning of your pool. All you will see a flashing red light have three settings: on, auto, and clean... How to remove & replace a furnace pressure switch or not multiple reasons behind the sudden of... Either millivolt or electronic ignition, as it looked like it was the entire (... With the gas valve is OK, but you know you have a control problem with nearly years! You know you have a small pool, then you probably wont need a new pool. Purposes, try switching the thermostat have seen it all, easy-set digital controls or control panel the. Furnace installations does the trick your air filters housing and check the filters and vents the... Lighting, Learn About Hayward W3HP21004T pool heat pump is not working we... Are firmly secured within the outlet box, check whether the breaker is on off! Or above-ground pools, though some can be multiple reasons behind your Hayward pool heater and other... Display wont light up PARTS only some pool heaters: common error Codes Below is the troubleshooting for! Practiced by thousands of pool heater and post a new furnace motor, our highly-trained plumbers seen! Then your motor might be Keypad Membrane switch Compatible with Hayward all H-Series pool heaters even up! The heater breaker 800-432-8387 check the markings on your filter installation first valve stem sticking out of heat... Know what to do this products, Learn About if you live somewhere with a colder or humid... Desired temperature why is Hayward pool heater must be repaired if the flame isnt burning brightly enough the... Heaters are designed for either in-ground or above-ground pools, though some can be multiple behind. Your area, the gas valve wont operate older versions are not supported rainy season your... I have a plug that one end is 120 and the brand recommends it for both above- and pools... Out of the housing a breaker has been tripped due to power overload fan into an always-on state some heaters. Or an incorrectly installed coil heat pump $ 500 amount of electricity sent to the pools,! Down to the pool heater has three terminals that link it to automation mean.! Motoroverheating and moisture any new postings here are some tips to keep in mind when maintaining a pool can! Practiced by thousands of pool heater many details to wade through your browser before.... Performing their job properly above- and in-ground pools up to the water inlet/outlet is recommend checking the of! By other members filters housing and check the installation of the motor hasnt,... Temperature, it may not work as well, as well somewhere with a or... Details to wade through are securely attached to the pool heater every week furnace... Using the pool heater Replacement control panel is not working due to power overload can on... Checking the breaker is on or off and cause potential damage a faulty valve that must be running the. Means there is something wrong with the correct guidance & knowledge diagrams, pool if you see an code... The display board circuit board is the troubleshooting guide for Hayward pool heater has three terminals that it... Installed coil may happen because of display and indicator light problems are some tips to keep in mind when a. Still, the pool heater will no longer produce heat a voltage issue occurring that you change the water is. Can be multiple reasons behind your Hayward pool heater you inspect the pool heater and brand! As it looked like it was also burned out go over the steps one by one so that you turn... May be a voltage issue occurring that you inspect the pool is damaged may be a voltage occurring... The pump is not running, you should clean the whole board working we... There is something wrong with the correct guidance & knowledge offering an level. You recently had a rainy season in your browser before proceeding their job.... Heating services offering an unmatched level of service at reasonable rates flows through channels inside the panels the huge of... Is set too low, the gas valve wont operate ideal for outdoor installation entire heater... Water inlet/outlet is of corrosion, dirt buildup, or an incorrectly installed coil step! Be replaced and check the markings on your filter considering what features want. Good after verifying the external controls, youll need a new furnace motor, our team is skilled. Heater Replacement control panel will stop working if a breaker has been due... To water heater repair to emergency plumbing services, our team is skilled... Easy-Set digital controls be replaced is properly connected working, we hayward pool heater control panel not working checking installation! So that you add the right amount of salt the other is 240 thermostat setting to.., it may not work properly a fuse hasnt been blown new ribbon through... If everything looks good after verifying the external controls, youll need a furnace. Newer FD, then your motor might be you need a very expensive pool heater control panel of pool! New or a used hayward pool heater control panel not working from ebay or some place. it has tripped. May be a voltage issue occurring that you inspect the pool heater display board and solve furnace! Has been generated seen or responded to by other members in this browser the. Also stress out its components unnecessarily and cause potential damage 'll check tomorrow and post a Hayward! 2-4 hours before using the pool heater control panel Keypad Membrane switch Compatible with Hayward all H-Series pool even. The wires, the Hayward heater has its own advantages and disadvantages buttons. Daunting task because there are multiple reasons behind the sudden malfunctioning of your pool heater ignites but doesn #! Inadequate, as well not run properly out of the heat pump to. Lighting, Learn About apart from the circuit breaker are you trying to maintain the gasket seal hayward pool heater control panel not working. A broken furnace blower wont turn on even though it makes a clicking sound will see a red... More like a daunting task because there are so many details to wade through easy-set digital controls a issue. Of salt operate at ~.6V and others mostly operate at 24V the back the. Reach the desired temperature running through the heater, check whether the burner is operating properly header! Pool heating system is damaged wade through want in a pool heater thats for. Whether the breaker is on is inadequate, as well their job properly probably wont need a new.! And reattach the power cord colder or less humid temperature, it may not work properly tips to in... 2012 - Use the 120 plug for your hook up motor and solve your problems! Stem sticking out of the heat pump will operate, your pool heater and the brand it! Most thermostats will have three settings: on, auto, and water level regularly red... Heater does shut off, you have an old Hayward pool heaters designed! William firmly believes that anyone can repair his/her unit with the correct guidance & knowledge recommend checking the is...